CRC1331169 | CCC1330676

813-643-8333

Sealed Roof Deck Checker: Does Your Roof Qualify?

Sealed Roof Deck Checker: Does Your Roof Qualify for the SWR Credit?

By Alex Sanchez, President, Certified Roofers & General Contractors, Inc. · Last updated

Short answer: Florida's wind mitigation form changed on April 1, 2026. A roof with two layers of felt or synthetic underlayment now counts as a sealed roof deck. If your roof was replaced in 2021 or later and your form says "No SWR," answer the five questions to see where you stand.

1. When was the roof last replaced?
2. What is under the shingles, tile or metal?
3. What does your current wind mitigation form say about secondary water resistance?
4. When was that inspection done?
5. Do you have paperwork showing the underlayment (permit, contract, invoice or job photos)?

What counts as a sealed roof deck on the 2026 form?

MethodCounts on the Rev. 04/26 form?
Full peel-and-stick underlayment (ASTM D1970)Yes
Self-adhering tape, 3.75 inches or wider, on every deck seam, plus underlaymentYes
Double layer of felt or synthetic (ASTM D226 Type II, D4869 Type III or IV, or D8257)Yes, new in 2026
Closed-cell spray foam on seams and rafters from the atticYes
One layer of felt or synthetic, no tapeNo
Hot-mopped feltNo

The full explanation, with the steps to get the credit added to your policy, is in what changed on Florida's wind mitigation form in 2026.

Frequently asked questions

What is a sealed roof deck?

A sealed roof deck, also called secondary water resistance or SWR, is a layer under the shingles, tile or metal that keeps rain out of the house if the roof covering blows off. Florida's wind mitigation form, OIR-B1-1802 (Rev. 04/26), gives an insurance credit for it.

What underlayment counts as a sealed roof deck in Florida?

Since April 1, 2026, the form accepts four methods: full peel-and-stick underlayment meeting ASTM D1970, self-adhering tape at least 3.75 inches wide over every deck seam, a double layer of felt or synthetic underlayment, or closed-cell spray foam from the attic. One layer of standard underlayment does not count.

Is this checker an official determination?

No. The checker is a guide from Certified Roofers & General Contractors, Inc. Only a qualified inspector can complete the wind mitigation form, and only your insurer decides what credit applies to your policy. Use the result to decide whether a new inspection is worth ordering.

Did we replace your roof?

Call us and we will pull your job file and tell you what underlayment is on your house. If someone else did it, we can still inspect the roof and tell you where you stand.

Request a free roof inspection Call (813) 643-8333

This tool is general guidance, not an inspection or an insurance determination. Discounts are set by each insurer.